–LCD Display: provide clear view of temperature, help you know the condition in an instant
–Safety: You can customize temperature and compressor delay, protecting your refrigeration/heating equipment according to your needs
–Easy to use: you can easily set it,only to need to press some keys
.
Description:
Name: Switch Socket
Series: 220 V
Package: electrostatic bag
Application fields: Electrical Engineering, electrical appliances
Purpose: digital temperature control
Power: 250v10a
Product Name:
Microcomputer temperature controller
Product model: xk-w2001
Temperature range: – 50 ~ 110'c
Temperature control range: – 50 ~ 110'c
Temperature measurement accuracy: 0.2'c
Temperature control accuracy: 0.1C
Measurement input: ntc10k L = 1m waterproof probe
Input power: 110V-220V (International Version)
Output power: 1500W
Output type: direct output
Output capacity: up to 10A
Appearance size: 120 * 59 * 30MM
PO setting start temperature
Press the setting button once to enter the internal menu, the default display is PO, press the setting button again, and set the required startup through the up and down buttons
temperature.
P1 set stop temperature
Press the setting button once to enter the internal menu, the digital display is PO, switch to P1 through the up and down buttons, and press the setting button again to pass
Set the required stop temperature by pressing the up and down buttons.
P2 set temperature correction
Enter the internal menu in the same way, switch to P2 by pressing the up and down buttons, press the setting button again, and set the required calibration through the up and down buttons
temperature. In the setting, if the detected temperature value is 0.5°C larger than the actual temperature value, then the calibration temperature that needs to be set is -0.5°C. If check
The measured temperature value is 1°C lower than the actual temperature value, and the calibration temperature that needs to be set is 1°C. Detection temperature + correction temperature = actual temperature.
P3 set delay start
Enter the internal menu in the same way, switch to P3 through the up and down keys, press the setting key again, and set the required delay time through the up and down keys
Time (in minutes). Delayed start is generally used for compressor refrigeration. If it is used for refrigerators and freezers, this value needs to be set.
The return pressure of the retractor is generally set to 3-6 minutes. If you are not used to control the compressor or do not need the delay function, just skip this item
Packing list:
Switch Socket*1
Note:
1.Please allow 0-1cm error due to manual measurement. Please make sure you do not mind before you bid.
2.Due to the difference between different monitors, the picture may not reflect the actual color of the item.
.